Omron XS5W-T421-CM1-K Industrial Ethernet Cable

SpecificationValue
ManufacturerOmron
ModelXS5W-T421-CM1-K
Product TypeIndustrial Ethernet Cable
Ethernet CategoryCat5e
Connector 1M12 Straight Plug
Connector 2M12 Straight Socket
Cable TypeSF/UTP Shielded
Cable Length1 m
Outer Sheath MaterialPVC
Outer Sheath ColorBlue
Cable Diameter6.5 mm
Installation TypeFixed Industrial Installation

The Omron XS5W-T421-CM1-K Industrial Ethernet Cable is intended for industrial communication systems that require secure M12 connectivity between Ethernet-enabled automation devices. The cable is designed according to Cat5e communication requirements and features a shielded construction that supports stable data transmission in electrically demanding industrial environments. According to the manufacturer, this model is supplied with a straight M12 plug on one end, a straight M12 socket on the opposite end, and a factory cable length of 1 meter.

Within modern automation systems, Ethernet communication extends beyond controllers and switches to include distributed I/O modules, industrial sensors, servo drives, operator interfaces, and machine vision equipment. The Omron XS5W-T421-CM1-K Industrial Ethernet Cable provides a practical solution where M12 industrial connectors are preferred because of their mechanical robustness and resistance to vibration.

Technical Description

This cable belongs to Omron’s XS5 Industrial Ethernet cable series and supports Cat5e network performance. Its SF/UTP shielded cable construction helps reduce the influence of electromagnetic interference generated by industrial machinery. The blue PVC outer jacket provides mechanical protection while simplifying cable identification during installation and maintenance.

The straight M12 connector arrangement allows direct connection between compatible field devices without requiring additional adapters. The one-meter cable length is suitable for panel wiring, machine interconnections, and localized network distribution.

Working Principle

The cable transmits Ethernet communication through balanced twisted conductor pairs that carry differential signals. Shielding surrounding the conductors helps minimize external electrical noise that could otherwise affect communication quality.

The M12 connector system establishes a mechanically secure connection that remains reliable under continuous machine vibration. Once connected, compatible Ethernet devices exchange data using standard industrial communication protocols supported by Cat5e infrastructure.

Typical Applications

  • Industrial Ethernet communication networks
  • PLC and remote I/O connections
  • Industrial network switches
  • Machine control systems
  • Servo drive communication
  • Machine vision installations
  • Factory automation equipment
  • Industrial communication cabinets

Industrial Applications

Automated Manufacturing Equipment

Production machinery often requires Ethernet communication between decentralized control devices. M12 connectivity provides a secure interface suitable for demanding industrial conditions.

Machine Building

Original equipment manufacturers frequently integrate standardized M12 Ethernet components to simplify installation, maintenance, and future equipment expansion.

Process Automation

Industrial processing systems use Ethernet networks to exchange operational data between controllers, field devices, and supervisory equipment. Shielded cabling contributes to dependable communication throughout the installation.

Omron XS5W-T421-CM1-K Advantages

  • Cat5e Industrial Ethernet performance
  • M12 plug to M12 socket configuration
  • SF/UTP shielded construction
  • Blue PVC industrial cable jacket
  • 1-meter cable length
  • Secure industrial connector design
  • Suitable for fixed automation installations
  • Supports industrial Ethernet communication infrastructure

Industry Examples

  • Automotive manufacturing
  • Electronics assembly
  • Food processing plants
  • Pharmaceutical production
  • Packaging machinery
  • Warehouse automation
  • Material handling systems
  • Industrial inspection equipment

Selection Considerations

When selecting an industrial Ethernet cable, engineers should verify connector type, shielding requirements, installation environment, communication category, and cable length. Confirming compatibility with connected equipment ensures reliable installation and simplifies maintenance.

Applications exposed to electrical noise benefit from shielded Ethernet cabling, while connector selection should match the interface requirements of field devices and industrial networking equipment.

Additional industrial networking components and related connectivity products can be explored through Omron sensor series.

Omron XS5W-T421-CM1-K Frequently Asked Questions

1. What type of cable is the Omron XS5W-T421-CM1-K Industrial Ethernet Cable?

It is a Cat5e shielded Industrial Ethernet cable with an M12 straight plug and an M12 straight socket.

2. What is the cable length?

The specified cable length is 1 meter.

3. Is the cable shielded?

Yes. It uses an SF/UTP shielded construction for industrial Ethernet communication.

4. Which connector types are provided?

The cable features a straight M12 plug on one end and a straight M12 socket on the other.

5. Where is this cable commonly installed?

It is typically used in industrial automation systems, machine control equipment, distributed I/O networks, and factory communication infrastructure.

6. Why are M12 connectors used in industrial Ethernet?

M12 connectors provide secure mechanical locking and reliable operation in environments exposed to vibration and demanding operating conditions.

7. Which communication networks can use this cable?

It is suitable for Cat5e-based industrial Ethernet installations, including systems using common industrial Ethernet protocols.

8. What should be verified before selecting the Omron XS5W-T421-CM1-K Industrial Ethernet Cable?

Engineers should confirm connector compatibility, required cable length, installation environment, shielding requirements, and network architecture before installation.