Omron XS5W-T421-BMC-Y Industrial Ethernet Cable

SpecificationValue
Product TypeIndustrial Ethernet Cable
Connector 1M12 Smartclick Straight Plug
Connector 2RJ45 Straight Plug
Ethernet CategoryCategory 5e
Cable TypeSF/UTP
Cable Length0.5 m
Sheath MaterialPVC
Outer Sheath ColorYellow
Cable Diameter6.5 mm
Suitable for RoboticsNo

Reliable communication is an essential requirement in industrial Ethernet networks where controllers, distributed I/O systems, HMIs, and field devices continuously exchange operational data. The Omron XS5W-T421-BMC-Y Industrial Ethernet Cable is designed to establish a secure connection between equipment equipped with an M12 Smartclick connector and devices using a standard RJ45 Ethernet interface. Manufactured as part of Omron’s Industrial Ethernet cable family, this model supports stable communication in fixed automation installations while complying with Cat5e network requirements. The specifications presented are based on the manufacturer’s official documentation. :contentReference[oaicite:0]{index=0}

The Omron XS5W-T421-BMC-Y Industrial Ethernet Cable is commonly integrated into machine-level Ethernet infrastructure where dependable signal transmission and organized cable routing are important for long-term system performance.

Omron XS5W-T421-BMC-Y Technical Description

This cable features a straight M12 Smartclick connector on one side and a straight RJ45 connector on the opposite side. It uses an SF/UTP shielded cable construction designed for Industrial Ethernet communication. The PVC outer sheath provides mechanical protection, while the distinctive yellow jacket simplifies cable identification inside complex electrical installations. The cable has a nominal length of 0.5 meter and a diameter of approximately 6.5 mm.

Omron XS5W-T421-BMC-Y Operating Principle

The cable functions as a passive transmission medium for Ethernet communication between compatible industrial devices. Data signals are carried through twisted-pair conductors that satisfy Category 5e transmission characteristics for Industrial Ethernet applications. The SF/UTP shielding helps minimize the influence of electromagnetic interference generated by nearby motors, servo drives, power supplies, and switching equipment.

The Smartclick M12 connector offers secure field-level connectivity, while the RJ45 connector enables straightforward integration with industrial switches, PLC Ethernet ports, industrial PCs, gateways, and communication modules.

Typical Applications

  • Industrial Ethernet communication networks
  • PLC control systems
  • Machine automation equipment
  • Industrial control cabinets
  • Vision inspection systems
  • Packaging machinery
  • Factory communication infrastructure
  • Automated assembly equipment

Omron XS5W-T421-BMC-Y Industrial Application Examples

Assembly Automation

Manufacturing cells often require reliable Ethernet communication between controllers, operator panels, and distributed I/O modules. Short communication cables help simplify equipment integration while maintaining organized wiring layouts.

Quality Inspection Systems

Industrial vision systems exchange inspection results with PLCs and supervisory systems using Industrial Ethernet networks. Stable communication contributes to consistent data transfer during continuous production.

Material Handling Equipment

Conveyor systems, barcode readers, and networked sensors frequently communicate through Industrial Ethernet infrastructure using compact cable assemblies installed inside machine frames and electrical cabinets.

Omron XS5W-T421-BMC-Y Advantages

  • Category 5e Industrial Ethernet performance
  • SF/UTP shielded cable construction
  • M12 Smartclick industrial connector
  • RJ45 standard Ethernet connector
  • PVC outer sheath for industrial environments
  • Yellow cable identification
  • Compact 0.5 m installation length
  • Suitable for fixed Industrial Ethernet installations

Factors to Consider Before Selecting the Cable

  • Confirm connector compatibility with connected devices.
  • Verify the required cable length before installation.
  • Determine whether the application requires fixed or robotic cable construction.
  • Evaluate the electromagnetic environment surrounding the installation.
  • Ensure compatibility with the intended Industrial Ethernet protocol.
  • Follow the manufacturer’s recommendations regarding cable routing and minimum bend radius.

Additional connectivity solutions and compatible cable families can be explored through the Omron sensor series.

Omron XS5W-T421-BMC-Y Frequently Asked Questions

1. What devices can be connected using this cable?

It is intended to connect equipment with an M12 Smartclick Ethernet interface to devices equipped with a standard RJ45 Ethernet port.

2. What Ethernet category does the cable support?

The manufacturer specifies Category 5e transmission performance.

3. Is this cable designed for robotic applications?

No. This model is intended for fixed industrial installations and is not specified as a robotic cable.

4. What shielding configuration is used?

The cable utilizes an SF/UTP shielded construction to improve communication stability in industrial environments.

5. Why does the cable have a yellow outer sheath?

The yellow jacket helps simplify visual identification during installation and maintenance of industrial Ethernet networks.

6. What is the cable length?

The standard factory length is 0.5 meter.

7. Which industrial sectors commonly use this cable?

It is widely applicable in automotive manufacturing, electronics production, packaging systems, warehouse automation, and machine building.

8. Can this cable be used with EtherCAT or EtherNet/IP systems?

Yes. As a Category 5e Industrial Ethernet cable, it is intended for Industrial Ethernet communication networks when installed according to the equipment manufacturer’s requirements.