Omron XS2W-T421-EM2-SS Industrial Ethernet Cable

FeatureValue
Product TypeIndustrial Ethernet Cable
Connector 1M12 Straight Plug (Male), D-coded
Connector 2M12 Straight Plug (Male), D-coded
Ethernet CategoryCat5e
Cable ConstructionSF/UTP Shielded
Cable Length3 m
Outer SheathPVC
Outer Diameter6.5 mm
Protection RatingIP67
Rated Voltage30 VDC
Rated Current3 A
Operating Temperature-25°C to +70°C

The Omron XS2W-T421-EM2-SS Industrial Ethernet Cable is developed for industrial Ethernet installations that require dependable communication between automation devices equipped with M12 D-coded interfaces. With a standard cable length of 3 meters, this model provides additional routing flexibility for larger machines, production cells, and distributed control systems while maintaining stable Fast Ethernet communication. Its shielded construction and rugged connector design make it suitable for industrial environments where vibration and electromagnetic interference are common.

Technical Description

The Omron XS2W-T421-EM2-SS Industrial Ethernet Cable features straight M12 male connectors with D-coding on both ends. This connector configuration is intended for Fast Ethernet communication in industrial automation systems. The cable complies with the Cat5e specification and incorporates an SF/UTP shielded structure that helps reduce electrical noise generated by nearby industrial equipment.

The assembly uses a durable PVC outer sheath with an approximate outer diameter of 6.5 mm. Its 3-meter cable length allows greater installation flexibility without requiring intermediate connection points. When correctly installed, the threaded M12 connectors provide an IP67 protection rating suitable for demanding industrial environments.

Working Principle

The cable transmits Ethernet communication signals between industrial devices using two shielded twisted pairs configured for Fast Ethernet operation. D-coded M12 connectors ensure proper signal assignment while the threaded locking mechanism secures the connection against vibration and accidental loosening.

The SF/UTP shielding minimizes electromagnetic interference generated by servo systems, motors, frequency converters, switching power supplies, and other industrial electrical equipment. This helps maintain communication reliability throughout machine operation.

Typical Applications

  • Industrial Ethernet communication
  • PLC networking
  • Remote I/O systems
  • Machine automation
  • Industrial control cabinets
  • Packaging machinery
  • Material handling systems
  • Factory automation networks

The Omron XS2W-T421-EM2-SS Industrial Ethernet Cable is suitable for installations where Ethernet-enabled automation devices require reliable communication over longer routing distances within industrial equipment.

Industrial Applications

Large manufacturing systems often require Ethernet communication across multiple machine sections. A 3-meter cable provides sufficient routing flexibility while maintaining standardized industrial connectivity between controllers, remote I/O stations, industrial switches, and intelligent field devices.

Automated production lines frequently install decentralized control components throughout conveyor systems, robotic workstations, and assembly equipment. Shielded Ethernet cables help maintain communication quality despite the presence of electrical interference from motors and motion control equipment.

Additional applications include pharmaceutical manufacturing, food processing equipment, warehouse automation, machine tool systems, electronics production, and automated inspection lines where durable Ethernet connections contribute to reliable industrial networking.

Advantages

  • Cat5e Fast Ethernet communication
  • M12 D-coded connectors on both ends
  • 3-meter cable for extended routing flexibility
  • SF/UTP shielded construction
  • Threaded vibration-resistant connectors
  • PVC industrial cable jacket
  • IP67 environmental protection
  • Suitable for demanding industrial automation systems

Industry Examples

Automotive Manufacturing

Ethernet-enabled robotic cells can communicate with decentralized control devices installed throughout production stations.

Warehouse Logistics

Distributed conveyor controllers and barcode reading systems can exchange operational data through secure industrial Ethernet connections.

Food Processing

Packaging machines and inspection equipment installed in production environments benefit from sealed M12 Ethernet connectivity.

Industrial Machinery

Machine builders can integrate controllers, Ethernet switches, and remote I/O modules using standardized M12 communication infrastructure.

Considerations When Selecting the Product

  • Verify that both connected devices use M12 D-coded Ethernet interfaces.
  • Confirm that a 3-meter cable length is appropriate for the installation.
  • Ensure compatibility with Cat5e Fast Ethernet communication.
  • Consider routing paths to avoid excessive mechanical stress.
  • Verify environmental requirements for IP67 protection.
  • Use proper connector tightening to maintain environmental sealing.

Omron XS2W-T421-EM2-SS Additional industrial networking products can be explored within the Omron sensor product families.

Omron XS2W-T421-EM2-SS Frequently Asked Questions

1. What type of connectors does this cable use?

It uses straight M12 male connectors with D-coding on both cable ends.

2. What Ethernet standard is supported?

The cable supports Cat5e Fast Ethernet communication.

3. How long is the cable?

The standard cable length is 3 meters.

4. Is the cable shielded?

Yes. It features an SF/UTP shielded construction to reduce electromagnetic interference.

5. What protection rating does it provide?

When properly installed, the connector assembly provides IP67 environmental protection.

6. Where is this cable typically used?

Typical applications include PLC communication, industrial Ethernet networks, machine automation, remote I/O systems, and factory networking.

7. Why are threaded M12 connectors important?

The threaded locking mechanism helps maintain secure electrical connections in environments exposed to vibration and continuous machine operation.

8. What should be verified before installation?

Connector compatibility, cable routing distance, Ethernet network requirements, environmental conditions, and proper installation torque should all be confirmed before commissioning.