Elesa+Ganter 113751 Electrical Column Level Indicator
Technical Overview
Elesa+Ganter 113751 electrical column level indicator corresponds to HCK.127-SST316-M12-FKM-PC-P-E-NC-80-NC. It is a stainless steel HCK.127 level indicator configured for oil level visibility, minimum level monitoring and maximum temperature signalling. The 127 mm hole centre distance and M12 threaded fixing points make it a practical choice for hydraulic tanks, lubrication units and compact fluid reservoirs.
The SST316 execution indicates AISI 316 stainless steel hardware, a valuable feature for machinery exposed to moisture, cleaning routines or harsher ambient conditions. FKM sealing rings are used for continuous working temperatures up to 130°C, while the transparent polycarbonate tube is specified for oil service. The removable PC front protection supports cleaning and helps protect the viewing column from direct contact.
NC Level and Temperature Logic
This model uses NC contact logic for both level and temperature functions. The minimum level contact is normally closed and opens when the minimum level is reached. The 80-NC temperature contact opens when the preset 80°C threshold is reached. This configuration is often preferred in monitoring circuits where a broken wire or open circuit condition must be easier to detect in the control system.
As an Elesa+Ganter 113751 electrical column level indicator, the product is especially relevant for maintenance teams that need both visual inspection and electrical feedback. More details about Elesa+Ganter hydraulic accessories can help compare sealing, tube and sensor options before final selection.
Elesa+Ganter 113751 FAQ
What product type is Elesa+Ganter 113751?
It is an electrical column level indicator with visual oil level display, minimum level monitoring and an 80°C normally closed temperature sensor.
Why choose the SST316 version?
AISI 316 stainless steel hardware provides stronger corrosion resistance than standard zinc-plated alternatives, making it useful in more demanding industrial settings.
What does NC mean in this model?
NC means normally closed. The circuit opens when the specified level or temperature condition is reached.
Can it be used near strong magnetic fields?
It should not be installed close to magnetic fields, because the level sensor relies on magnetic activation from the float mechanism.