Elesa+Ganter 113435 Oil Level Indicator

The Elesa+Ganter 113435 oil level indicator is a technical monitoring component for hydraulic systems where visual level reading and electrical minimum-level control are both important. Its full configuration, HCK.127-SST-M12-FKM-PC-P-80-NC, identifies a 127 mm column oil level indicator with stainless-steel fixing hardware, M12 thread, FKM sealing, polycarbonate tube, front protection and a normally closed electrical level sensor suitable for applications up to 80°C.

Built for Hydraulic Level Monitoring

This product is part of the HCK family of column level indicators. The assembly ends are made from black glass-fibre reinforced polyamide-based technopolymer, while the support is aluminium. The transparent PC tubular window enables direct visual checking of oil level, and the white graduated contrast screen improves readability from the front and side positions.

The P execution adds removable transparent polycarbonate front protection. This is valuable in machine environments where cleaning, accidental contact or oil mist may affect the exposed viewing column. The SST execution uses AISI 303 stainless steel screws and AISI 304 stainless steel nuts and washers, supporting durability in industrial environments.

Elesa+Ganter 113435  Electrical Sensor Function

The NC configuration means the electrical contact opens when the minimum level is reached. This logic is often chosen for monitoring circuits where loss of continuity can indicate a low-level condition. In practical terms, the indicator can help operators identify level changes visually while also supporting machine control systems with a signal.

The Elesa+Ganter 113435 oil level indicator is a strong fit for hydraulic units, lubrication reservoirs, oil circulation systems, industrial presses and automated machinery. For more information about compatible Elesa+Ganter product families, visit Elesa+Ganter.

Elesa+Ganter 113435  FAQ

What is Elesa+Ganter 113435 used for?

It is used to monitor oil level in hydraulic and lubrication systems, combining visual indication with an electrical minimum-level signal.

What does NC mean?

NC means normally closed. In this configuration, the contact opens when the monitored minimum level is reached.

What does the 80 marking refer to?

It refers to the sensor configuration for applications up to 80°C.

Why is front protection useful?

The P front protection helps shield the transparent viewing tube and can be removed for cleaning, making the indicator easier to maintain.

Is this product suitable for oil?

Yes. The PC tubular window version is intended for oil applications, especially where direct visual level checking is required.