Elesa+Ganter 113025-KN Electrical Level Indicator for Oil Reservoir Monitoring

Elesa+Ganter 113025-KN electrical level indicator is supplied under the stock designation HCK.127-ZN-M12-NBR-PC-P-E-NC-STL-KN. It is designed for applications where oil level must be checked visually while also being monitored through an electrical minimum-level contact and temperature probe. This makes the component useful in hydraulic systems, lubrication tanks, industrial machinery, compact power packs, and service-focused reservoir designs.

Key Technical Identity

The HCK.127 format refers to the 127 mm fixing distance. ZN identifies zinc-plated steel screws, nuts, and washers, while M12 indicates the fixing thread. NBR refers to the synthetic rubber O-ring material, commonly used in oil-related industrial assemblies. PC indicates a transparent polycarbonate level tube, and P identifies the removable polycarbonate front protection.

Electrical Monitoring Function

This model uses an E-type minimum level sensor with NC contact logic. In practical terms, the normally closed contact opens when the liquid reaches the minimum level threshold. For machine builders and maintenance teams, that behaviour can be useful in fail-aware circuits where a change of state must clearly identify a low-fluid condition.

Temperature Probe Advantage

The STL suffix confirms the presence of a PT100 temperature electrical probe. In many oil reservoirs, fluid level alone is not enough to understand system health. Temperature gives additional context: rising oil temperature can indicate overload, restricted flow, insufficient cooling, or early-stage component wear. Combining level and temperature information in one component reduces panel complexity and supports cleaner machine design.

Why This Version Matters

The Elesa+Ganter 113025-KN electrical level indicator is not just a viewing accessory. It is a compact monitoring interface for systems where operators need reliable visual confirmation and control systems need electrical feedback. The removable protection, clear column, aluminium support, and engineered polymer ends make it suitable for demanding industrial environments when installed according to the application requirements.

For more details, visit Elesa+Ganter technical components.

FAQ

What is the full product type of Elesa+Ganter 113025-KN?

It is an electrical column level indicator with NC minimum level contact and PT100 temperature probe.

What does the PC tube indicate?

PC refers to a transparent polycarbonate tube, generally used for oil level visibility.

Why is the NC contact useful?

It opens when the minimum level is reached, allowing control systems to detect a low-level event through a clear state change.

Is the front protection removable?

Yes. The P configuration identifies removable polycarbonate front protection, useful during cleaning and inspection.