Eleasa+Ganter 11054 HCV.76-E-ST-NO-80-M10 Electrical Level Indicator

Technical Overview

The Elesa+Ganter 11054 HCV.76-E-ST-NO-80-M10 electrical level indicator is designed for hydraulic reservoirs where visual oil level checking and electrical monitoring are both required. As an HCV.76 series component, it combines a transparent polyamide-based technopolymer body with a built-in MIN level sensor and an 80°C maximum temperature sensor. This makes it useful in systems where oil level and thermal condition must be monitored from a compact, panel-mounted device.

Elesa+Ganter 11054 HCV.76-E-ST-NO-80-M10 Material and Construction

The body is made from transparent PA-T technopolymer, a material selected for resistance to shocks, oils with additives, hydrocarbons, solvents and demanding industrial fluids. The indicator uses zinc-plated steel screws, nuts and washers, while sealing is supported by step-shaped packing rings and an NBR synthetic rubber O-ring. The visual column provides clear fluid visibility, including from side positions, supported by a lens effect for easier level reading.

Sensor Function

This model uses a normally open contact configuration. In practical terms, the electrical contact closes when the oil level drops to the minimum threshold or when the preset temperature of 80°C is reached. The MIN level sensor supports AC/DC supply, with maximum applicable voltage values of 140 Vac and 200 Vdc for the NO configuration. The maximum switching current is 1 A, and the maximum current for the NO contact is 1.2 A.

Elesa+Ganter 11054 HCV.76-E-ST-NO-80-M10 Application Notes

The HCV.76 format is suitable for mineral oil applications, with floating ensured for fluids above 800 kg/m³ density. Laboratory testing with mineral oil type CB68 at 23°C indicates strong weld resistance for the HCV.76 size. It should not be mounted close to magnetic fields, as this may affect sensor operation. For more information about Elesa+Ganter, users can review compatible hydraulic accessories and related indicator solutions.

Elesa+Ganter 11054 HCV.76-E-ST-NO-80-M10 FAQ

What is the Elesa+Ganter 11054 HCV.76-E-ST-NO-80-M10 used for?

It is used to visually monitor oil level and electrically detect minimum oil level or a maximum temperature condition in hydraulic reservoirs.

What does NO mean in this model?

NO means normally open. The contact closes when the minimum level or 80°C temperature threshold is reached.

Does this indicator include a temperature sensor?

Yes. The model includes a maximum temperature sensor with an 80°C trigger point.

What product type is this component?

It is an electrical level indicator for hydraulic systems.

Can it be used with all fluids?

It is primarily intended for mineral oil applications. For other fluids, suitability should be checked under actual working conditions.