Omron MY4IN-D2-GS-R DC24 Power Relay: Technical Guide, Applications and Installation
The Omron MY4IN-D2-GS-R DC24 is a Power Relay developed for engineers who understand that the cost of an unplanned stop far exceeds the cost of a quality component. Rated at 24V DC, it addresses real challenges found in DC power control systems without overcomplicating installation or maintenance.
Omron’s product range extends well beyond relays and switches. The company’s Omron Sensor portfolio covers inductive, photoelectric, and capacitive detection technologies — often integrated into the same panel alongside units like this one, creating a fully cohesive control system.
Understanding the Omron MY4IN-D2-GS-R DC24 Power Relay
The Omron MY4IN-D2-GS-R DC24 is a Power Relay rated at 24V DC, built to handle DC power control systems reliably over a long service life. Key engineering features include diode coil, led indicator, gs rail compatible, retaining clip, and the unit mounts via gs din rail socket.
Technically, the Omron MY4IN-D2-GS-R DC24 delivers diode coil, led indicator, gs rail compatible, retaining clip. Matching the 24V DC control bus requires no extra hardware, which keeps commissioning time short and the panel design clean.
Core Specifications
The table below summarises the main technical parameters of the Omron MY4IN-D2-GS-R DC24. For full specifications, always refer to the official Omron product datasheet, as application-specific derating may apply.
| Parameter | Value |
|---|---|
| Product Type | Power Relay |
| Coil / Operating Voltage | 24V DC |
| Contacts / Channels | 4-pole (4PDT) |
| Contact Current | 10 A |
| Key Features | Diode coil, LED indicator, GS rail compatible, retaining clip |
| Mounting | GS DIN rail socket |
| Mechanical Lifetime | 10 million mechanical operations |
| Operating Temperature | -25 °C to +70 °C |
| Compatible Socket | GS series socket |
Application Scenarios
The Omron MY4IN-D2-GS-R DC24 Power Relay is commonly specified for the following applications:
- Dc power control systems
- Production line panels
Across these use cases, the consistent thread is a need for dependable switching over a large number of operations, often in environments where an unplanned fault would create significant disruption. The Omron MY4IN-D2-GS-R DC24 is designed with exactly those conditions in mind.
The Omron MY4IN-D2-GS-R DC24 is designed to be used with GS series socket. Using a non-compatible socket model can compromise contact pressure and reduce overall service life, so always verify socket compatibility before ordering.
Getting It Right at Installation
A few installation details make a tangible difference with the Omron MY4IN-D2-GS-R DC24 Power Relay. Using the correct Omron socket eliminates contact resistance mismatch. Leaving adequate clearance around the unit supports thermal dissipation in dense panel layouts. And ensuring terminal screw torque is within spec prevents the kind of creeping resistance that causes intermittent faults months later.
For ongoing maintenance, periodically inspect for contact discolouration, check terminal screws for loosening, and look for any signs of heat stress on the housing. Catching these early avoids the much larger cost of an unplanned production stop.
Why Engineers Choose Omron
Specifying the Omron MY4IN-D2-GS-R DC24 Power Relay also means specifying into an ecosystem. Omron’s portfolio covers relays, sensors, PLCs, power supplies, and more — all engineered to work together. When a component does eventually need replacing, compatibility with the rest of the system is guaranteed, which is something off-brand alternatives simply cannot offer.
Frequently Asked Questions
How do I install the Omron MY4IN-D2-GS-R DC24?
Mount the Omron MY4IN-D2-GS-R DC24 Power Relay on a 35 mm DIN rail using the compatible socket or directly as specified. De-energise the circuit before installation, connect cables at the rated cross-section, and tighten terminal screws to the torque values stated in the datasheet.
What is the electrical lifespan of the Omron MY4IN-D2-GS-R DC24?
Electrical lifespan depends on switching frequency and load type. At rated resistive load, Omron relay products typically achieve several hundred thousand to over a million operations. The exact figure for the Omron MY4IN-D2-GS-R DC24 is stated in its technical datasheet.
Can the Omron MY4IN-D2-GS-R DC24 switch inductive loads?
Yes, but inductive loads reduce contact lifespan due to higher arc energy at switch-off. For frequent inductive switching with the Omron MY4IN-D2-GS-R DC24 Power Relay, a suppression device — such as a varistor or RC snubber — is recommended across the load.
Is the Omron MY4IN-D2-GS-R DC24 RoHS compliant?
Omron products conform to the RoHS Directive requirements. Specific compliance documentation for the Omron MY4IN-D2-GS-R DC24 can be requested from your authorised Omron distributor.
What should I check during periodic maintenance of the Omron MY4IN-D2-GS-R DC24?
Inspect contact surfaces for pitting or discolouration, check terminal screws for loosening (particularly in high-vibration environments), and verify that the housing shows no thermal discolouration. Replace the unit if any of these signs are present.

